Midwest Technologies, Inc. of IllinoisSpringfield, IL 62703MID-TECHMIDWEST TECHNOLOGIES, INC.®ARC-6000LIQUID/GRANULARAPPLICATION CONTROL SYSTEMUSER G
ARC 600098-05017Rev.- 11-6CE & STANDARD VERSION1.5. BOOM SECTION “ON/OFF” INDICATORSThe boom section on/off indicators (lower right, labeled “BOO
2-198-0501 Rev.- 1ARC 6000CE & STANDARD VERSION2.0. CALIBRATION AND SET UPNOTE: PLEASE READ THROUGH THE FOLLOWING SECTIONS COMPLETELY BEFORE YOU
98-05017Rev.- 12-2ARC 6000CE & STANDARD VERSION2.2.2. CHANGING UNITS (LIQUID APPLICATOR ONLY)To change units, set the Mode switch to “OPERATE” an
2-398-0501 Rev.- 1ARC 6000CE & STANDARD VERSIONA. Set the console to the following positions;Power ONMode Selector SET- UPDisplay Selector IMPL. W
98-05017Rev.- 12-4ARC 6000CE & STANDARD VERSIONOnce the initial calibration number has been entered into the console, proceed to section 2.6.1.4 t
2-598-0501 Rev.- 1ARC 6000CE & STANDARD VERSIONB. Hold INC/DEC switch to DEC until console reads PSi 0Note: A display reading of "PSi - -&qu
98-05017Rev.- 12-6ARC 6000CE & STANDARD VERSION7. Start the main carrier pump, Rotate the display selector switch to "TEST SPEED". Turn
2-798-0501 Rev.- 1ARC 6000CE & STANDARD VERSION2.6.1.5. SETTING THE CORRECTION FACTOR (Psi Mode)If you will be spraying water solutions, the corre
98-05017Rev.- 12-8ARC 6000CE & STANDARD VERSIONEnter this calibration number into the console memory using the procedure that follows.A. Set the
2-998-0501 Rev.- 1ARC 6000CE & STANDARD VERSIONSelector switch back to OPERATE, the corrected Indicated Amount will be displayed. If this number
CHANGE LOGDATE: DATE CODE: PAGES AFFECTED: SW VERSION05/15/00 00136 New Manual - CE Certified Console 2.03IIARC 600098-05017Re
98-05017Rev.- 12-10ARC 6000CE & STANDARD VERSION5. Return the Mode Select switch to the OPERATE position and check to see that the accumulated dis
2-1198-0501 Rev.- 1ARC 6000CE & STANDARD VERSIONTo select the desired response:A. Set the console switches to the following positions:Power ONMode
98-05017Rev.- 12-12ARC 6000CE & STANDARD VERSIONB. Use the INC/DEC switch to set the desired full load capacity.C. Return the Mode Selector switch
3-198-05017Rev.- 1ARC 6000CE & STANDARD VERSION3.0. OPERATIONUnder normal operating conditions, the MIDWEST TECHNOLOGIES control system is automat
98-05017Rev.- 13-2ARC 6000CE & STANDARD VERSION3.3. CHANGING APPLICATION RATEThe operator has chosen a desired application rate and entered this v
3-398-05017Rev.- 1ARC 6000CE & STANDARD VERSION3.5. RAPID UNLOAD USING THE CONVEYOR (GRANULAR APPLICATION)Use the following procedure to operate
98-05017Rev.- 13-4ARC 6000CE & STANDARD VERSIONThis page purposely left blank
4-198-05017Rev.- 1ARC 6000CE & STANDARD VERSION4.0. MAINTENANCEMIDWEST TECHNOLOGIES recommends the following maintenance to keep your control syst
98-05017Rev.- 14-2ARC 6000CE & STANDARD VERSION4.4. FLOW SENSOR (LIQUID APPLICATION)Prior to each day’s spraying, the flow sensor should be inspe
5-198-05017Rev.- 1ARC 6000CE & STANDARD VERSION5.0. TROUBLE SHOOTING THE ARC SYSTEMTrouble shooting of the MIDWEST TECHNOLOGIES control system beg
ARC 6000III98-05017Rev.- 1CE & STANDARD VERSIONCHANGE LOG ...
98-05017Rev.- 15-2ARC 6000CE & STANDARD VERSION5.4. ERROR MESSAGE “Err-1, 2, 3, 4, & 5,” INVALID OPERATIONAny time the control console senses
5-398-05017Rev.- 1ARC 6000CE & STANDARD VERSION5.4.5. ERROR MESSAGE "Err 5"The "Err 5/Pump L or C" message indicates that the
98-05017Rev.- 15-4ARC 6000CE & STANDARD VERSION
6-198-05017Rev.- 1ARC 6000CE & STANDARD VERSION6.0. EMERGENCY OPERATIONSMIDWEST TECHNOLOGIES has gone to great lengths to make the ARC System as
98-05017Rev.- 16-2ARC 6000CE & STANDARD VERSIONapplication rate at the target speed. Adjust the pump bypass valve (if one is provided) or manually
A-198-05017Rev.- 1ARC 6000CE & STANDARD VERSIONAPPENDIX AA-0. APPENDIX A - DRAWINGS
98-05017Rev.- 1A-2ARC 6000CE & STANDARD VERSIONA-1 ARC FLOW/PRESSURE BASED - WIRING DIAGRAMARC 6000, WIRING DIAGRAM(Flow/Pressure based)Fuse,(10 a
A-398-05017Rev.- 1ARC 6000CE & STANDARD VERSIONA-2 ARC FLOW/PRESSURE BASED - PLUMBING DIAGRAMSupply TankCarrier PumpBypass Line Supply LineRegulat
98-05017Rev.- 1A-4ARC 6000CE & STANDARD VERSIONVALUES DISPLAYED BY ARC-6000FILL OUT BEFORE CALLING FOR FASTER SERVICESOFTWARE VERSION: _________
B-198-05017Rev.- 1ARC 6000CE & STANDARD VERSIONAPPENDIX B
ARC 600098-05017Rev.- 1IVCE & STANDARD VERSION4.0. MAINTENANCE ...
98-05017Rev.- 1B-2ARC 6000CE & STANDARD VERSIONB.0. INTRODUCTIONCongratulations and welcome to the latest in the world of precision chemical appli
B-398-05017Rev.- 1ARC 6000CE & STANDARD VERSIONB.2. ARC SYSTEM COMPONENT PARTSThere are five major components in a complete ARC system, a console,
98-05017Rev.- 1B-4ARC 6000CE & STANDARD VERSIONSometimes an applicator is already equipped with a flowmeter. The ARC system can usually be adapte
B-598-05017Rev.- 1ARC 6000CE & STANDARD VERSIONthe ARC console and allows connection of up to five boom control switches (or solenoids), one statu
98-05017Rev.- 1B-6ARC 6000CE & STANDARD VERSIONThis page purposely left blank
C-198-05017Rev.- 1ARC 6000CE & STANDARD VERSIONAPPENDIX C
98-05017Rev.- 1C-2ARC 6000CE & STANDARD VERSIONC.0. INSTALLATIONC.1. CONTROL CONSOLE INSTALLATIONThe ARC control console should be located inside
C-398-05017Rev.- 1ARC 6000CE & STANDARD VERSIONC.1.2. CONSOLE CABLE ROUTINGConsole cable routing is important. There are five individually labele
98-05017Rev.- 1C-4ARC 6000CE & STANDARD VERSIONC.2. INSTALLING APPLICATION RATE SENSORSC.2.1. FLOWMETER/PRESSURE SENSOR (FLOW SENSOR) INSTALLATION
C-598-05017Rev.- 1ARC 6000CE & STANDARD VERSIONC.2.2. RATE SENSOR INSTALLATIONThe installer should refer to the detailed instructions shipped with
ARC 60001-198-05017Rev.- 1CE & STANDARD VERSION1.0. SWITCHES AND CONTROLS%RateDISPLAY SELECTORSpeedField Area Impl.WidthDistance Test SpeedPrimeTo
98-05017Rev.- 1C-6ARC 6000CE & STANDARD VERSIONSpeedometer Sensor: If installed on a vehicle with a two speed axle, be sure the sensor is mounted
ARC 600098-05017Rev.- 11-2CE & STANDARD VERSION1.4. DISPLAY SELECTORThe Display Selector (right center) is used to select and display the various
ARC 60001-398-05017Rev.- 1CE & STANDARD VERSIONOFF SET- UP DEC.ON OPERATE INC.ARC-6000AutomaticRate ControllerMID-TECHMIDWEST TECHNOLOGIES, INC.1
ARC 600098-05017Rev.- 11-4CE & STANDARD VERSIONOFF SET- UP DEC.ON OPERATE INC.ARC-6000AutomaticRate ControllerMID-TECHMIDWEST TECHNOLOGIES, INC.1
ARC 60001-598-05017Rev.- 1CE & STANDARD VERSIONOFF SET- UP DEC.ON OPERATE INC.ARC-6000AutomaticRate ControllerMID-TECHMIDWEST TECHNOLOGIES, INC.1