Seitenansicht 24
2-9
98-05018
R2
CE & StandardVersion
TASC 6100
Setup
& Cal.
Use the following procedure to set the All Booms OFF
response.
A. Set the console to the following positions;
1. Power ON
2. Mode Selector OPERATE
3. Display Selector Impl. Width
4. Boom switches OFF
(or Master switch)
B. Hold the INC./DEC. switch up to display the current
setting (Hold or Close). Continuing to hold the
switch up causes the display to alternate between the
two options at about three to ten second intervals.
The option appearing in the display when the INC.
Switch is released is the response selected.
SETTING THE GROUND SPEED OVERRIDE (GSO)
VALUE
T
o use the GSO feature, set the GSO value to the
minimum ground speed you want to control to
when the GSO switch is activated. This should be
the lowest speed at which the vehicle can dispense
material satisfactorily. If you do not intend to use this
feature, set this value to zero (0.0). (See page 1-7 for a
more complete description of GSO operation.)
Use the following procedure to set the GSO Speed.
A. Set the console to the following positions;
1. Power ON
2. Mode Selector SET-UP
3. Display Selector Speed
B. Use the INC./DEC. switch to set the GSO speed to the
desired value.
CAUTION: When traveling at a speed slower than the
GSO speed setting, this feature will cause the product to
be applied at a rate consistent with the GSO speed,
rather than the true ground speed, possibly resulting in
serious over application. When Ground Speed Over-
ride is being used, and the true ground speed is less
DISPLAY SELECTOR
Speed
Area Impl. Width
Distance
Test
Speed
PSI/Prime
Total Applied
Application Rate
OFF SET- UP DEC.
ON
OPERATE INC.
Scan
Product Vol.
Fan RPM
BOOMS
123456789
% Rate
A-1
A-2
A-3
C
MASTER
ON
OFF
MI
B
DISPLAY SELECTOR
Speed
Area Impl. Width
Distance
Test
Speed
PSI/Prime
Total Applied
Application Rate
OFF SET- UP DEC.
ON
OPERATE INC.
Scan
Product Vol.
Fan RPM
BOOMS
123456789
% Rate
A-1
A-2
A-3
B
M
id
-T
Mid-T
e
c
h
ech
Seitenansicht 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 85 86

Kommentare zu diesen Handbüchern

Keine Kommentare